Alternative prosthetic vascular access creation using subscapular artery as inflow to prevent dialysis access related steal syndrome
In patients highly suspected of developing steal syndrome, the subscapular artery may be a good supplier for functional prosthetic arteriovenous access, as well as a good solution for the prevention of steal syndrome. A 51-year-old woman was preparing to have a loop shaped polytetrafluoroethylene (P...
Gespeichert in:
Veröffentlicht in: | Annals of surgical treatment and research 2015, 88(6), , pp.349-352 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In patients highly suspected of developing steal syndrome, the subscapular artery may be a good supplier for functional prosthetic arteriovenous access, as well as a good solution for the prevention of steal syndrome. A 51-year-old woman was preparing to have a loop shaped polytetrafluoroethylene (PTFE) graft placed at the left upper extremity. The diameter of subscapular the artery was 3 mm. Arterial calcification was not evident. The diameter of the basilic vein was 6 mm. A 50-cm long 4-7 mm tapered PTFE graft was placed in a loop shape between both skin incisions. The patient was uneventfully discharged at postoperative day 4 without any remaining steal syndrome. The PTFE graft was well-functioning during the follow-up period. The patient did not experience symptoms of steal syndrome any longer. |
---|---|
ISSN: | 2288-6575 2288-6796 |
DOI: | 10.4174/astr.2015.88.6.349 |