펄스차이 폴라로그래피를 이용한 갑상선기능조절 약제 중의 2-mercapto-1-methyl-imidazole 분석
The determination of 2-mercapto-1-methyl-imidazole (MMI) in 5.0${\times}10^{-2}$ M lithium perchlorate suporting electrolyte has been investigated by the differential pulse polarography. The optimum condition of MMI analysis was as follows; -0.9 volts initial potential, 0.08 mV pulse height, 2 mV/se...
Gespeichert in:
Veröffentlicht in: | Journal of the Korean Chemical Society 2004, 48(2), , pp.137-143 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | kor |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The determination of 2-mercapto-1-methyl-imidazole (MMI) in 5.0${\times}10^{-2}$ M lithium perchlorate suporting electrolyte has been investigated by the differential pulse polarography. The optimum condition of MMI analysis was as follows; -0.9 volts initial potential, 0.08 mV pulse height, 2 mV/sec scan rate, and medium mercury drop size. Standard calibration curve showed a good linearlity in the range of 1.0${\times}10^{-7}M\;to\;8.0{\times}10^{-5}$ M and the detection limit has been (2.2${\pm}0.1){\times}0.1^{-9}$ M. This method was applicated for the determination of MMI in antithyroid drug without interference of additives. 5.0${\times}10^{-2}$ M LiClO4 지지전해질에서 2-mercapto-1-methyl-imidazole(MMI)의 분석을 펄스차이폴라로그래피로 조사하였다. MMI의 분석에서 적절한 조건은 다음과 같다; 초기전위: -0.9 volts, 펄스세기: 0.08 mV, 주사속도: 2 mV/sec. 표준검량곡선은 1.0${\times}10^{-7}{\sim}8.0{\times}10^{-5}$ M 범위에서 좋은 직선성을 보였으며, 검출한계는 (2.2${\pm}0.1){\times}0.1^{-9}$ M이었다. 이 방법으로 첨가제의 방해없이 항갑상선 약제중의 MMI를 정량하는데 응용하였다. |
---|---|
ISSN: | 1017-2548 2234-8530 |