Effect of Different Guide Vane Numbers on Transient Radial Force of Pump as Turbine
Guide vane was added to pump as turbine (PAT), the transient flow characteristics of PAT were calculated and experimented under different guide vane numbers. The results show that after the PAT was added guide vane, the distribution of speed streamline and blade load is more uniform than before, and...
Gespeichert in:
Veröffentlicht in: | International journal of fluid machinery and systems 2018, 11(1), 38, pp.115-122 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Guide vane was added to pump as turbine (PAT), the transient flow characteristics of PAT were calculated and experimented under different guide vane numbers. The results show that after the PAT was added guide vane, the distribution of speed streamline and blade load is more uniform than before, and the unsteady radial force on impeller decreased greatly, which is good for the stability of PAT's operation. When the guide vane number is equal to 9, both the maximum radial force difference and dominant frequency amplitude of radial force are the minimum. So there is an optimal guide vane number, for the given geometric parameters of PAT. |
---|---|
ISSN: | 1882-9554 1882-9554 |
DOI: | 10.5293/IJFMS.2018.11.1.115 |