PROTECTION SEQUENCE OF AC/DC CONVERTERS FOR ITER PF MAGNET COILS
The protection sequence of an AC/DC converter for an ITER PF coil system is developed in this study. Possible faults in the coil system are simulated and the results reflected in the design of a sequence to protect the coil and converter. The inductances of the current sharing reactors and thyristor...
Gespeichert in:
Veröffentlicht in: | Nuclear engineering and technology 2010, 42(3), , pp.305-312 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The protection sequence of an AC/DC converter for an ITER PF coil system is developed in this study. Possible faults in the coil system are simulated and the results reflected in the design of a sequence to protect the coil and converter. The inductances of the current sharing reactors and thyristor numbers in parallel with the bridge arms are optimized with the designed protection sequence. KCI Citation Count: 1 |
---|---|
ISSN: | 1738-5733 2234-358X |
DOI: | 10.5516/NET.2010.42.3.305 |