제왕절개 전신마취시 Isoflurane과 Sevoflurane이 임산부의 각성에 미치는 영향

It is hard to choose suitable plan of general anesthesia for cesarean section on guarantee of fetal safety and maternal awareness. We compared the effect of 0.8% isoflurane with that of 1.25% sevoflurane on maternal awareness using isolation forearm technique and bispectral index. Methods: Thirty pa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Korean journal of anesthesiology 2008, 54(5), , pp.524-530
Hauptverfasser: 천은희, 김종학, 백희정, 김윤진
Format: Artikel
Sprache:kor
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:It is hard to choose suitable plan of general anesthesia for cesarean section on guarantee of fetal safety and maternal awareness. We compared the effect of 0.8% isoflurane with that of 1.25% sevoflurane on maternal awareness using isolation forearm technique and bispectral index. Methods: Thirty parturients presenting for elective cesarean section under general anesthesia were randomly assigned to receive either 0.8% isoflurane or sevoflurane 1.25% for maintenance by fetal expulsion. Maternal awareness monitoring was assessed by isolation forearm technique and bispectral index at 1 minute intervals. Results: Although bispectral index values after intubation 1 minute and 4 minutes were lower in sevoflurane group, no differences were detected in maternal awareness using isolation forearm technique between two groups. Postoperative recall was not detected in both groups. In neonatal outcome, there were no differences in Apgar scores. Acidity was significantly increased (P < 0.05) in umbilical vein gas analysis after sevoflurane administration but it was within normal limits. Conclusions: The incidence of maternal awareness was high and there were no differences between two groups during cesarean section under general anesthesia. It is hard to choose suitable plan of general anesthesia for cesarean section on guarantee of fetal safety and maternal awareness. We compared the effect of 0.8% isoflurane with that of 1.25% sevoflurane on maternal awareness using isolation forearm technique and bispectral index. Methods: Thirty parturients presenting for elective cesarean section under general anesthesia were randomly assigned to receive either 0.8% isoflurane or sevoflurane 1.25% for maintenance by fetal expulsion. Maternal awareness monitoring was assessed by isolation forearm technique and bispectral index at 1 minute intervals. Results: Although bispectral index values after intubation 1 minute and 4 minutes were lower in sevoflurane group, no differences were detected in maternal awareness using isolation forearm technique between two groups. Postoperative recall was not detected in both groups. In neonatal outcome, there were no differences in Apgar scores. Acidity was significantly increased (P < 0.05) in umbilical vein gas analysis after sevoflurane administration but it was within normal limits. Conclusions: The incidence of maternal awareness was high and there were no differences between two groups during cesarean section under general anesthesia. KCI Ci
ISSN:2005-6419
2005-7563