Endotracheal intubation using i-gel® and lightwand in a patient with difficult airway: a case report

This case report involves tracheal intubation using i-gel® in combination with a lightwand in a patient with a difficult airway, classified as Cormack-Lehane grade 3. I-gel® was used during anesthesia induction to properly maintain ventilation. The authors have previously reported successful trachea...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Korean journal of anesthesiology 2015, 68(5), , pp.501-504
Hauptverfasser: Choi, Chun Gil, Yang, Ki-Hwan, Jung, Jong-Kwon, Han, Jeong Uk, Lee, Choon Soo, Cha, Young-Deog, Song, Jang-Ho
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This case report involves tracheal intubation using i-gel® in combination with a lightwand in a patient with a difficult airway, classified as Cormack-Lehane grade 3. I-gel® was used during anesthesia induction to properly maintain ventilation. The authors have previously reported successful tracheal intubation on a patient with a difficult airway through the use of i-gel® and a fiberoptic bronchoscope. However, if the use of a fiberoptic bronchoscope is not immediately available in a patient with a difficult airway, tracheal intubation may be performed by using i-gel® and a lightwand in a patient with difficult airway, allowing the safe induction of anesthesia.