Cementless Revision Total Hip Arthroplasty with Ceramic Articulation

The results of ceramic-on-ceramic (CoC) bearing surfaces in primary total hip arthroplasty (THA) were well known. However, it was not known in revision THA. The purpose of this study is to report the results of revision THA with ceramic articulation. A total of 112 revision THAs were evaluated. The...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Hip & pelvis 2015, 27(4), , pp.223-231
Hauptverfasser: Yang, Jong-Hyuck, Yang, Seong-Jo, Kang, Joon-Soon, Moon, Kyoung-Ho
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The results of ceramic-on-ceramic (CoC) bearing surfaces in primary total hip arthroplasty (THA) were well known. However, it was not known in revision THA. The purpose of this study is to report the results of revision THA with ceramic articulation. A total of 112 revision THAs were evaluated. The mean age at the time of surgery was 51.6 years (27.7 to 84.2 years). The mean duration of the follow-up periods was 6.3 years (2.3 to 11.4 years). The Harris hip scores improved from an average of 56.2 at the index surgery to an average of 93.3 at the last follow-up (P
ISSN:2287-3260
2287-3279