경동맥 화학색전술을 위한 간동맥 혈관조영술에서 Ioversol 320과 비교한 Iopamidol 250의 영상 화질 비교 분석과 조영제 유해반응 평가
Purpose This study aimed to compare the image quality and adverse events between Iopamidol 250 and Ioversol 320 usage during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). Materials and Methods Medical records and hepatic angiography from 113 patients who underwe...
Gespeichert in:
Veröffentlicht in: | Journal of the Korean Society of Radiology 2020, 81(1), , pp.166-175 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng ; kor |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose This study aimed to compare the image quality and adverse events between Iopamidol 250 and Ioversol 320 usage during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). Materials and Methods Medical records and hepatic angiography from 113 patients who underwent TACE with Iopamidol 250 (44 patients) and Ioversol 320 (69 patients) were retrospectively reviewed. Vessel perception on hepatic angiography was graded into three categories by two radiologists for hepatic subsegmental arteries, the right gastroepiploic artery, right gastric artery, and pancreaticoduodenal artery. Imaging concordance was assessed by comparing the number of detected HCCs on hepatic angiography and CT. The adverse events before and after hepatic angiography were evaluated. Results The mean vessel perception scores were 2.92 and 2.94 for Iopamidol 250 and Ioversol 320, respectively. The imaging concordance was 31 (70.5%) and 46 (66.7%) patients for Iopamidol 250 and Ioversol 320, respectively. There were no statistical differences in vessel perception or imaging concordance (p > 0.05). One and six patients experienced nausea for Iopamidol 250 and Ioversol 320, respectively. There was no statistical difference in adverse events (p = 0.24). Conclusion Iopamidol 250 can be used in hepatic angiography for TACE without significant difference in image quality or occurrence of adverse events from Ioversol 320. 목적 간세포암의 화학색전술에 사용되는 조영제인 Ioversol 320과 Iopamidol 250을 영상 화질과 유해반응에서 차이가 있는지 비교 분석하고자 하였다. 대상과 방법 경동맥 화학색전술을 시행 받은 113명의 간세포암 환자를 대상으로 후향적으로 분석하였고, Iopamidol 250은 44명, Ioversol 320은 69명에게 주입하였다. 영상 화질은 혈관인지도 및 일치도로 평가하였다. 혈관인지도는 두 명의 영상의학과 전문의가 간동맥 혈관조영술에서 간세분엽동맥, 췌십이지장동맥, 우위동맥, 우위대망동맥이 보이는 인지도와 명확도에 따라 3단계로 점수화하였다. 일치도는 혈관조영술과 전산화단층촬영에서 발견된 간세포암 수를 비교하였다. 시술 전후 임상증상을 조사하여 조영제 유해반응을 평가하였다. 결과 혈관인지도의 평균 점수는 Iopamidol 250은 2.92점, Ioversol 320은 2.94점이었다. 일치도는 Iopamidol 250은 31명(70.5%), Ioversol 320은 46명(66.7%)이 일치했으며, 혈관인지도와 일치도는 통계적 유의한 차이가 없었다(p > 0.05). Iopamidol 250은 1명, Ioversol 320은 6명의 환자가 오심을 호소하였으며, 유해반응 빈도의 유의한 차이는 없었다(p = 0.24). 결론 간세포암 화학색전술에서 Iopamidol 250은 Ioversol 320과 영상의 화질 및 유해반응에 유의한 차이가 없이 사용될 수 있을 것으로 생각된다. |
---|---|
ISSN: | 1738-2637 2288-2928 2951-0805 |
DOI: | 10.3348/jksr.2020.81.1.166 |