Development of a Novel Intraoperative Neuromonitoring System Using an Accelerometer Sensor in Thyroid Surgery: A Porcine Model Study

The sensitivity and positive predictive value of widely used intraoperative neuromonitoring (IONM) using electromyography (EMG) of the vocalis muscle in thyroid surgery are controversial. Thus, we developed a novel IONM system with an accelerometer sensor that uses the piezoelectric effect instead o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical and experimental otorhinolaryngology 2019, 12(4), , pp.420-426
Hauptverfasser: Sung, Eui-Suk, Lee, Jin-Choon, Shin, Sung-Chan, Kwon, Hyun-Geun, Na, Han-Seul, Park, Da-Hee, Choi, Seong-Wook, Ro, Jung-Hoon, Lee, Byung-Joo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The sensitivity and positive predictive value of widely used intraoperative neuromonitoring (IONM) using electromyography (EMG) of the vocalis muscle in thyroid surgery are controversial. Thus, we developed a novel IONM system with an accelerometer sensor that uses the piezoelectric effect instead of EMG to detect laryngeal twitching. The objective of this study was to evaluate the feasibility and safety of this novel IONM system during thyroid surgery in a porcine model. We developed an accelerometer sensor that uses the piezoelectric effect to measure laryngeal twitching in three dimensions. This novel accelerometer sensor was placed in the anterior neck skin (transcutaneous) or postcricoid area. Stimulus thresholds, amplitude, and latency of laryngeal twitching measured using the accelerometer sensor were compared to those measured through EMG of the vocalis muscle. The amplitudes of the accelerometer sensor at the anterior neck and postcricoid area were significantly lower than those of EMG because of differences in the measurement method used to evaluate laryngeal movement. However, no significant differences in stimulus thresholds between the EMG endotracheal tube and transcutaneous or postcricoid accelerometer sensors were observed. Accelerometer sensors located at the anterior neck or postcricoid area were able to identify laryngeal twitching. The stimulus intensity measured with these sensors was equivalent to that from conventional vocalis EMG. Our novel IONM system with an accelerometer sensor that checks changes in surface acceleration can be an alternative to EMG of the vocalis muscle for IONM in the future.
ISSN:1976-8710
2005-0720