Minimum 2-Year Experience with Magnetically Controlled Growing Rods for the Treatment of Early-Onset Scoliosis: A Systematic Review
Magnetically controlled growing rods have been used to treat early-onset scoliosis for the last 9 years; however, few studies have been published, with only short-term follow-up. The aim of the present study is to systematically review the outcomes of magnetically controlled growing rods in the trea...
Gespeichert in:
Veröffentlicht in: | Asian spine journal 2019, 13(4), , pp.682-693 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Magnetically controlled growing rods have been used to treat early-onset scoliosis for the last 9 years; however, few studies have been published, with only short-term follow-up. The aim of the present study is to systematically review the outcomes of magnetically controlled growing rods in the treatment of early-onset scoliosis with a minimum of 2-year follow-up. Studies were included if patients with early-onset scoliosis (scoliosis diagnosed before 10 years of age) underwent implantation of magnetically controlled growing rods with a minimum of 2-year follow-up. The literature review and data extraction followed the established preferred reporting items for systematic review and meta-analysis guidelines. Data of distraction frequency, number of distractions, distracted length, Cobb angle, kyphosis, T1-T12 length, and T1-S1 length preoperatively, postoperatively, and at final follow-up were collected. Data regarding complications and unplanned reoperations were also extracted. The mean values of these parameters were calculated, or pooled meta-analysis was performed if available. Ten articles were included in this systematic review, with a total of 116 patients and a follow-up period between 23 and 61 months. The mean preoperative Cobb angle and kyphosis angle were 60.1° and 38.0°, respectively, and improved to 35.4° and 26.1° postoperatively. At final follow-up, the Cobb and kyphosis angles were maintained at 36.9° and 36.0°, respectively. The average preoperative T1-T12 and T1-S1 lengths were 180.6 mm and 293.6 mm, respectively, and increased to 198.3 mm and 320.3 mm postoperatively. T1-T12 and T1-S1 lengths were 212.3 mm and 339.3 mm at final follow-up, respectively. The overall rate of patients with complications was 48% (95% confidence interval [CI], 0.38-0.58) and unplanned reoperation 44% (95% CI, 0.33-0.55) after sensitivity analysis. The current evidence from different countries with a minimum of a 2-year follow-up suggests that magnetically controlled growing rods are an effective technique to treat pediatric scoliosis and promote spine growth. However, nearly half of patients still developed complications or required unplanned reoperations. |
---|---|
ISSN: | 1976-1902 1976-7846 |
DOI: | 10.31616/asj.2018.0272 |