Enzyme-linked immunosorbent assay for detecting anti-pertussis toxin antibody in mouse

Although the DTaP and Tdap vaccines used to prevent pertussis have been used for a long time, there is no standard method for measuring pertussis antigens. Therefore, this preliminary study was conducted to develop an enzyme-linked immunosorbent assay method using an animal model for measuring antib...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical and experimental vaccine research (Seoul) 2019, 8(1), , pp.64-69
Hauptverfasser: Choi, Gi Sub, Huh, Dong Ho, Han, Seung Beom, Ahn, Dong Ho, Kang, Kyu Ri, Kim, Ji Ahn, Choi, Bo Mi, Kim, Hea Ryun, Kang, Jin Han
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Although the DTaP and Tdap vaccines used to prevent pertussis have been used for a long time, there is no standard method for measuring pertussis antigens. Therefore, this preliminary study was conducted to develop an enzyme-linked immunosorbent assay method using an animal model for measuring antibodies against pertussis toxin, the most important pertussis pathogenic antigen, in the sera of vaccinated mice. Tohama phase I was cultured for 24-30 hours, and then pertussis toxin was purified from the culture medium by chromatography. Purified pertussis toxin was diluted in phosphate-buffered saline-coating buffer, and 100 µL of diluted pertussis toxin was added to each well and reacted at room temperature for 4 hours. Positive serum was diluted to 1/1,250-1/80,000 and negative serum was diluted to 1/50 to determine the coating concentration with the optimal signal/noise ratio. Optimal test conditions were confirmed from the dilution factors of the secondary antibody and streptavidin horseradish peroxidase (SA-HRP). Optimal conditions were as follows: 4 µg/mL for coating antigen; 1/40,000 for secondary antibody; and 1/1,000 for the SA-HRP dilution factor. Comparison of the sera obtained from mice treated with a developing vaccine and commercial vaccine with National Institute for Biological Standard and Control standard serum under the established conditions showed the following results: 1,300.62, 534.94, and 34.85, respectively. The method developed in this study is suitable for measuring anti-pertussis toxin antibodies and may be applicable for clinical sample analysis or indirect diagnosis of pertussis.
ISSN:2287-3651
2287-366X
DOI:10.7774/cevr.2019.8.1.64