국내에서 치료된 고정성, 가철성, 그리고 임플란트 보철물의 수명 및 성공률 분석
Purpose: The purpose of this study is to analyze the factors affecting the longevity of failed prosthesis and the success rate of the prosthesis based on the data evaluated with the newly developed Korean Academy of Prosthodontics (KAP) criteria. Materials and methods: Evaluation was performed in th...
Gespeichert in:
Veröffentlicht in: | Taehan Chikwa Poch'ol Hakhoe chi 2018, 56(2), , pp.95-104 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | kor |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose: The purpose of this study is to analyze the factors affecting the longevity of failed prosthesis and the success rate of the prosthesis based on the data evaluated with the newly developed Korean Academy of Prosthodontics (KAP) criteria. Materials and methods: Evaluation was performed in the restored prosthesis for patients who visited the prosthodontics department of the 13 dental university hospitals and general hospitals. The status of the prosthesis was classified into four categories: Good, Fair, Bad, Worst. The success was recorded if only the category was classified in 'good'. The mean duration of failed prostheses and the success rate through Kaplan-Meier method were analyzed. Results: A total of 1,804 cases of prosthesis were evaluated: 810 cases of fixed dental prostheses (FDP), 519 cases of Removable Dental Prostheses (RDP), and 475 cases of implant prosthesis. The mean duration of failed FDP was $11.41{\pm}0.30years$ and the median was 10 years. The mean duration of failed RDP was $8.18{\pm}0.29years$ and the median was 7 years. The mean duration of failed implant prosthesis was $7.99{\pm}0.30years$ and the median was 7 years. The factors related to the failure were as follows: number of units, abutments, abutments treated with root canal, and plaque index in FDPs; treated and opposing dentition in RDPs; the number of implants, duration of use, and plaque index in implant prostheses. Conclusion: The average duration of failed prosthesis was 11.41 years for FDPs, 8.18 years for RDPs, and 7.99 years for implant prosthesis, according to the evaluation with newly developed KAP criteria. 목적: 이 연구의 목적은 새롭게 개발된 대한치과보철학회의 보철물 평가 기준을 적용하여 고정성, 가철성 그리고 임플란트 보철물의 성공과 실패를 평가함으로써 보철물의 수명과 이에 관련된 요인을 분석하는 데 있다. 대상 및 방법: 전국 13개 대학/종합병원 보철과에 내원한 환자들을 대상으로 구강내 사용중인 보철물을 평가하였다. 대한치과보철학회의 기준에 따라, 수는 성공, 우, 양, 가는 실패로 규정하고, 실패한 보철물의 평균 사용기간과 실패와 관련된 요인을 분석하였다. Kaplan-Meier 분석에 의한 성공률을 분석하였다. 결과: 고정성 보철 810 증례, 가철성 보철 519 증례, 그리고 임플란트 보철 475 증례, 총 1,804 증례가 연구에 포함되었다. 검사 시점에 실패로 판정된 보철물의 평균 사용기간은 고정성 보철물은 $11.41{\pm}0.30$년, 중간값은 10년이었고, 가철성 보철물은 $8.18{\pm}0.29$년, 중간값 7년이었으며, 임플란트 보철물은 $7.99{\pm}0.30$년, 중간값은 7년이었다. 실패와 관련있는 요인 중 고정성보철물은 유닛 수, 지대치 수, 근관치료된 지대치 수, 치태지수였고, 가철성 보철물의 경우 대합치였으며 임플란트 보철의 경우 임플란트 개수, 사용기간, 치태지수였다. 결론: 대한치과보철학회의 기준으로 보철물을 평가한 결과, 실패한 보철물의 평균수명은 고정성 11.41년, 가철성 8.18년, 그리고 임플란트 보철물은 7.99년이었다. |
---|---|
ISSN: | 0301-2875 2005-3789 |
DOI: | 10.4047/jkap.2018.56.2.95 |