Improvement of Intermittent Advancing Accuracy of Pneumatic Cylinder-Driven Roll Feeder

A proposed pneumatic cylinder-driven roll feeder and an air press were designed to be operated automatically by a PLC. The accuracy of the intermittent feed pitch of the roll feeder was evaluated by measuring lengths of cut-offs of a strip stock by a digimatic vernier caliper. At each predetermined...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the Korean Society of Manufacturing Technology Engineers 2016, 25(3), , pp.164-170
1. Verfasser: So, Jung Duck
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A proposed pneumatic cylinder-driven roll feeder and an air press were designed to be operated automatically by a PLC. The accuracy of the intermittent feed pitch of the roll feeder was evaluated by measuring lengths of cut-offs of a strip stock by a digimatic vernier caliper. At each predetermined feed pitch, the proposed roll feeder was tested 100 times by varying the feed/cut intervals as 2.0/1.5, 3.0/2.0, and 3.5/2.5 s as test sets. The lengths of the cutoffs of the strip stock ranged from 9.89-10.34, 12.1-12.65, and 15.21-15.67 mm at the predetermined 10, 12, and 15 mm feed pitch, respectively, among the total of 300 samples in each feed pitch, regardless of the feed/shear interval. Therefore, the feed/cut interval at each selected feed pitch was found to have no effect on the accuracy of the intermittent advancing of the strip stock. KCI Citation Count: 0
ISSN:2508-5093
2233-6036
2508-5107
DOI:10.7735/ksmte.2016.25.3.164