Determination of Slenderness Ratio of Faceplates in Steel-Plate Composite Wall Panels
Modular Steel-plate Composite (SC) construction reduces the construction time and labor requirement in their implementation for nuclear plants. For an effective structural design using SC wall panel, non-slender member is preferred for a faceplate of SC wall panel to satisfy the strength limit and t...
Gespeichert in:
Veröffentlicht in: | KSCE Journal of Civil Engineering 2019, 23(2), , pp.691-698 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Modular Steel-plate Composite (SC) construction reduces the construction time and labor requirement in their implementation for nuclear plants. For an effective structural design using SC wall panel, non-slender member is preferred for a faceplate of SC wall panel to satisfy the strength limit and the serviceability limit. The existing specifications developed for SC wall panel construction suggest width-to-thickness ratios (or faceplate slenderness ratios); however, these ratios differ in various specifications. This paper recommends the slenderness ratio of faceplates in SC wall panel. The results reveal that the faceplate slenderness ratio, the ratio of
b
/
t
p
, should be less than or equal to 0.907
E
s
/
F
y
. In addition, the maximum stud (or tie) spacing will be a useful parameter to be considered during fabrication of SC wall, for structural design and also for field applications. |
---|---|
ISSN: | 1226-7988 1976-3808 |
DOI: | 10.1007/s12205-018-0144-1 |