Triplet 열교환기를 사용하는 소형 J-T 냉동기

Most J-T (Joule-Thomson) refrigerators use a Giaque-Hampson type heat exchanger due to its excellent thermal performance and compactness. The cryoprobe (cryosurgical probe) treating prostate cancer usually has a dimension of 17 gauge (1.6 mm diameter), so it does not have enough space to bear a Giaq...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:한국초전도.저온논문지, 11(1) 2009, 11(1), , pp.60-63
Hauptverfasser: 황규완, 정상권
Format: Artikel
Sprache:eng ; kor
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Most J-T (Joule-Thomson) refrigerators use a Giaque-Hampson type heat exchanger due to its excellent thermal performance and compactness. The cryoprobe (cryosurgical probe) treating prostate cancer usually has a dimension of 17 gauge (1.6 mm diameter), so it does not have enough space to bear a Giaque-Hampson type heat exchanger. In this paper, the triplet heat exchanger is adopted as the heat exchanger of cryoprobe, and the performance is investigated with an experimental test. The result shows that the triplet heat exchanger can be substituted for Giaque-Hampson type heat exchanger in the application of cryosurgery.
ISSN:1229-3008
2287-6251