Beam Position Monitor for the PAL-XFEL Laser Heater
A beam position monitor (BPM) has been developed to monitor the position of an electron beam in the laser heater of the X-ray free electron laser at the Pohang Accelerator Laboratory (PALXFEL). The BPM for the laser heater (LH-BPM) is based on a strip-line type. The LH-BPM consists of a pair of uppe...
Gespeichert in:
Veröffentlicht in: | Journal of the Korean Physical Society 2018, 73(8), , pp.1131-1136 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A beam position monitor (BPM) has been developed to monitor the position of an electron beam in the laser heater of the X-ray free electron laser at the Pohang Accelerator Laboratory (PALXFEL). The BPM for the laser heater (LH-BPM) is based on a strip-line type. The LH-BPM consists of a pair of upper and lower blocks. Two strip-lines are in each block. In this paper, we report on the physical motivation, design considerations, cold tests, and typical results for the LH-BPM currently in use at the PAL-XFEL. |
---|---|
ISSN: | 0374-4884 1976-8524 |
DOI: | 10.3938/jkps.73.1131 |