잔류농약 다성분 동시분석을 위한 기체 크로마토그래피 분석성능과 3종 분배용매에 의한 농약추출

In order to develop the simultaneous analytical method for pesticide residues which ones in soil are rapidly and inexpensively measured by, many analytical methods for individual pesticide residue and several methods for multi-pesticide residues in agricultural commodities and food were reviewed. Va...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:농약과학회지 2009, 13(3), , pp.133-147
Hauptverfasser: 김찬섭(Chan-Sub Kim), 김진배(Jin-Bae Kim), 임건재(Geon-Jae Im), 박현주(Hyun-Ju Park), 이영득(Young-Deuk Lee)
Format: Artikel
Sprache:kor
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In order to develop the simultaneous analytical method for pesticide residues which ones in soil are rapidly and inexpensively measured by, many analytical methods for individual pesticide residue and several methods for multi-pesticide residues in agricultural commodities and food were reviewed. Various gas chromatographic conditions and pre-treatment procedures were intensively investigated and modified. And then new optimum procedure was established and its proficiency was validated. The response on detectors of simultaneous determination of 180 pesticides out of pesticides used in Korea was tested. The number of pesticides that their limits of detection (LOD) equal or lower than $0.05\;mg\;kg^{-1}$ were 137 pesticides on ECD, 170 pesticides on NPD and 179 pesticides on ECD/NPD integrated. The retention times of most pesticides ranged appropriately between 10 minutes and 40 minutes in the proposed chromatographic conditions. But about 90 pesticides eluded between 20 minutes and 30 minutes and so they were not resolved enough. In partition with dichloromethane, ethyl acetate/hexane (1:1) and ethyl acetate, number of pesticides whose extraction efficiency ranged from 70% to 120%, were 163, 154 and 147, respectively. 토양 중 농약잔류량을 신속하고 저렴하게 분석할 수 있는 다성분 동시분석법을 개발하기 위하여 작물체 중 잔류농약분석법 및 개별성분 분석법을 조사하고 확인하여 기기분석 조건을 확립하였고 분배과정의 용매별 효율성을 조사한 결과는 다음과 같았다. 국내사용농약 중 GC로 분석 가능한 성분 180 성분에 대하여 검출기별 감응성 검토결과 ECD의 경우 84 성분 및 NPD의 경우 113 성분이 예상검출한계 $0.01\;mg\;kg^{-1}$ 이하이었으며 ECD와 NPD를 종합하면 148 성분이었다. 검출한계 $0.05\;mg\;kg^{-1}$ 이하인 농약성분은 ECD 137 성분 및 NPD 170 성분이었고, 두 검출기의 결과를 종합하면 179 성분이 예상 검출한계 $0.05\;mg\;kg^{-1}$ 이하이었다. 농약성분 peak의 분리도와 분석소요시간을 고려하여 선정한 기기분석 조건에서의 머무름 시간 분포를 살펴보면 대부분의 성분이 시료주입 후 10 분에서 40 분 사이에 검출되어 적절하게 분포되었으나, 20 분과 30 분사이의 머무름 시간대에는 90 여 성분이 분포하여 많은 성분이 충분히 분리가 되지 않을 것으로 판단되었다. 분배과정의 회수율은 dichlorornethane이 가장 우수하였으며, 그 다음은 ethyl acetate/hexane 혼합용매, ethyl acetate 순으로 각각 시험대상 성분의 90%, 85% 및 81%가 70-120% 범위의 회수율을 나타내었다. 따라서 dichlorornethane을 두 분배용매체계로 대체하는 것이 가능할 것으로 사료된다.
ISSN:1226-6183
2287-2051