액체크로마토그래피를 이용한 농산물중 pyribencarb와 대사물 KIE-9749의 잔류 분석법

The aim of this study was to develop an analytical method for the determination of pyribencarb and its metabolite KIE-9749 in agricultural commodities. The experiment was performed with a range of concentrations $0.05{\sim}2.5{\mu}g/g$ in apple, green pepper, potato, hulled rice, soybean, pear, peac...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:농약과학회지 2016, 20(3), , pp.236-246
Hauptverfasser: 권혜영(Hyeyoung Kwon), 홍수명(Su-Myeong Hong), 김택겸(Taek-Kyum Kim), 김형진(Hyung-Jin Kim), 문병철(Byeong-Chul Moon), 경기성(Kee-Sung Kyung)
Format: Artikel
Sprache:kor
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of this study was to develop an analytical method for the determination of pyribencarb and its metabolite KIE-9749 in agricultural commodities. The experiment was performed with a range of concentrations $0.05{\sim}2.5{\mu}g/g$ in apple, green pepper, potato, hulled rice, soybean, pear, peach, grape and cucumber. Each samples were extracted with acetone and cleaned by dichloromethane/saline water partition and purified with Florisil solid phase extraction (SPE) cartridge and aminopropyl SPE cartridge. Pyribencarb and KIE-9749 were separated and quantified by HPLC/UVD at 265nm using acetonitrile and water as mobile phase. The recoveries of pyribencarb and KIE-9749 were within 78.3~108.4% and 73.9~113.7% with RSD below 12.2% and 15.0%, respectively. The limits of quantification (LOQ) were both $0.05{\mu}g/g$. LC/ESI-MS/MS was optimized for confirmation of residue identity. 농산물중 pyribencarb와 그 대사물 KIE-9749의 잔류분석법을 개발하였다. 분석법 개발에 사용된 농산물은 5대 작물군의 대표작물인 사과, 고추, 감자, 현미, 대두와 잔류허용기준이 설정된 배, 복숭아, 오이, 포도였다. 각 농산물은 아세톤으로 추출하였으며 액-액분배를 이용하여 1차 정제하고 Florisil solid phase extraction (SPE) cartridge와 aminopropyl SPE cartridge를 이용하여 2차 정제를 실시하는 조건을 확립하였다. 기기분석 조건은 HPLC/UVD 265 nm 파장에서 acetonitrile과 물을 이동상으로 사용하여 확립하였다. 확립된 분석법을 분석자를 달리하여 검증한 결과 pyribencarb의 회수율과 RSD값은 78~108%, 2.7~12.2%였으며, KIE-9749의 회수율과 RSD값은 74~114%와 1.7~15.0%를 보였다. 분석법의 정량한계(LOQ)는 두 성분 모두 $0.05{\mu}g/g$이었으며 LC/ESI-MS/MS를 사용하여 확립된 정성조건에서 방해 피크는 발견되지 않았다. 확립된 분석법은 pyribencarb와 그 대사물 KIE-9749에 대한 농산물의 안전성 검사를 위해 사용될 수 있을 것이다.
ISSN:1226-6183
2287-2051
DOI:10.7585/kjps.2016.20.3.236