Aortic Injury during Transforaminal Lumbar Interbody Fusion
Aortic injury during transforaminal lumbar interbody fusion (TLIF) is a rare but severe complication. We experienced aortic injury during TLIF at L3-4 with a 59-year-old woman diagnosed with an adjacent segment disease at L3-4. Severe bleeding occurred during disc space expansion, and the blood pres...
Gespeichert in:
Veröffentlicht in: | Korean Journal of Spine 2017, 14(3), , pp.118-120 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Aortic injury during transforaminal lumbar interbody fusion (TLIF) is a rare but severe complication. We experienced aortic injury during TLIF at L3-4 with a 59-year-old woman diagnosed with an adjacent segment disease at L3-4. Severe bleeding occurred during disc space expansion, and the blood pressure dropped to 60/40 mmHg. The patient's vital sign stabilized after compression with gauze and Gelfoam in addition to blood transfusion. The patient was treated with endovascular repair using a percutaneous technique after intertransverse fusion at L3-4 was completed. She recovered and is being followed-up in the outpatient department. |
---|---|
ISSN: | 1738-2262 2586-6583 2093-6729 2586-6591 |