Experimental investigation of beam-to-column connection with SHN490 steel under cyclic loading
Seismic performance of beam-to-column connections used in the middle-low rise buildings was investigated through the cyclic loading test. Four joint specimens were prepared in accordance with the variables of material and connection type. In two cases of welded connection, the brittle fracture in we...
Gespeichert in:
Veröffentlicht in: | International journal of steel structures 2016, 16(4), , pp.1299-1307 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Seismic performance of beam-to-column connections used in the middle-low rise buildings was investigated through the cyclic loading test. Four joint specimens were prepared in accordance with the variables of material and connection type. In two cases of welded connection, the brittle fracture in weld did not occur but cracked at heat-affected zone (HAZ) and/or near weld access hole. In the connections with extended end-plate, punching failure followed by end-plate failure occurred at the flange of column around bolt head. The moment capacities based on failure modes were calculated and compared with the test results. The connections were classified as rigid, semi-rigid, flexible in terms of bending stiffness and strength. |
---|---|
ISSN: | 1598-2351 2093-6311 |
DOI: | 10.1007/s13296-016-0092-x |