Experimental and numerical studies on pressure drop in reverse electrodialysis: Effect of unit cell configuration
Experimental and numerical studies on pressure drop in Reverse electrodialysis (RED) were performed. In this study, a module with 200 unit cells is considered for the demonstration of bench-scale RED module and two different unit cell configurations are utilized. Pressure drop through the module is...
Gespeichert in:
Veröffentlicht in: | Journal of mechanical science and technology 2016, 30(11), , pp.5287-5292 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Experimental and numerical studies on pressure drop in Reverse electrodialysis (RED) were performed. In this study, a module with 200 unit cells is considered for the demonstration of bench-scale RED module and two different unit cell configurations are utilized. Pressure drop through the module is measured by varying flow rates. For evaluating the hydrodynamic characteristics in the unit cell, a numerical simulation is also conducted and the simplified method using a porous media model is employed to simulate the channel filled with spacer. Due to the insertion of spacer and narrow channel, great pressure loss occurs along the unit cell. Based on estimated pressure data, high pressure difference between seawater and fresh water channel takes place locally in the unit cell configuration with crossflow direction, leading to a leakage problem through the membrane and finally degradation in the output power. Consequently, it is confirmed that the unit cell configuration is one of the important design parameters in a RED module. |
---|---|
ISSN: | 1738-494X 1976-3824 |