Aortic Valve Replacement Using Balloon Catheter for Thoracic Endovascular Aortic Repair to Patient with Calcified Aorta

A 79-year-old man was admitted to Samsung Changwon Hospital due to chest pain and dyspnea. The ejection fraction was 31% and mean pressure gradient between the left ventricle and aorta was 69.4 mmHg on echocardiography. Chest computed tomography showed severe calcification of the ascending aorta. Ao...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of chest surgery 2013, 46(3), , pp.212-215
Hauptverfasser: 김인석, 변정훈, 유병하, 김한용, 황상원, 송윤규
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A 79-year-old man was admitted to Samsung Changwon Hospital due to chest pain and dyspnea. The ejection fraction was 31% and mean pressure gradient between the left ventricle and aorta was 69.4 mmHg on echocardiography. Chest computed tomography showed severe calcification of the ascending aorta. Aortic valve replacement was successfully performed using a thoracic endovascular aortic repair balloon catheter without classic aortic cross clamping. The patient was discharged on the eleventh postoperative day. KCI Citation Count: 0
ISSN:2765-1606
2765-1614