Nonisotropic Propagation of Light in Human Forearm
Light propagation in the skin of the human forearm was investigated in vivo and in situ. In this study, a sensitive photomultiplier tube with a spectral range of 300 650 nm was used to detect the extremely weak light that is propagated in skin from 17 mm up to 33 mm. We devised a control system that...
Gespeichert in:
Veröffentlicht in: | Journal of the Korean Physical Society 2006, 48(II), , pp.307-312 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Light propagation in the skin of the human forearm was investigated in vivo and in situ. In this study, a sensitive photomultiplier tube with a spectral range of 300 650 nm was used to detect the extremely weak light that is propagated in skin from 17 mm up to 33 mm. We devised a control system that enabled us to guide the optical fibers so that the input and the detection could be exactly located on the skin in complete darkness. We obtained an effective attenuation coefficient whose values were 0.21 ± 0.03 cm.1 and 0.28 ± 0.06 cm.1 in the longitudinal and the transversal directions, respectively, over a long distance ( 17 mm). Those value were much smaller than the previously known value of 2.7 3.3 cm.1 for a short distance ( 2 mm). In addition, we found that light propagated better longitudinally than transverse, which contrasted with the isotropic propagation at short distances. These results might have significance for phototherapy. Light propagation in the skin of the human forearm was investigated in vivo and in situ. In this
study, a sensitive photomultiplier tube with a spectral range of 300 650 nm was used to detect
the extremely weak light that is propagated in skin from 17 mm up to 33 mm. We devised a control
system that enabled us to guide the optical fibers so that the input and the detection could be
exactly located on the skin in complete darkness. We obtained an effective attenuation coefficient
whose values were 0.21 ± 0.03 cm.1 and 0.28 ± 0.06 cm.1 in the longitudinal and the transversal
directions, respectively, over a long distance ( 17 mm). Those value were much smaller than the
previously known value of 2.7 3.3 cm.1 for a short distance ( 2 mm). In addition, we found
that light propagated better longitudinally than transverse, which contrasted with the isotropic
propagation at short distances. These results might have significance for phototherapy. KCI Citation Count: 0 |
---|---|
ISSN: | 0374-4884 1976-8524 |