Optical-Amplifier Noise-Figure Measurement by Q-Factor Analysis

In the semi-classical picture of linear optical ampliers, the amplier output is considered as a mixture of an amplied signal and amplied spontaneous emission (ASE). The amplied signal is a coherent eld with Poisson statistics, and the ASE can be well described as a thermal eld. This simple picture,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the Korean Physical Society 2003, 43(51), , pp.714-721
1. Verfasser: Kweon, Gyeong-il
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In the semi-classical picture of linear optical ampliers, the amplier output is considered as a mixture of an amplied signal and amplied spontaneous emission (ASE). The amplied signal is a coherent eld with Poisson statistics, and the ASE can be well described as a thermal eld. This simple picture, however, can be fully justied quantum mechanically. It has been shown that the signal-to-noise ratio, and hence the noise gure of a linear optical amplier, can be determined by measuring the Q-factor of the amplied continuous wave (CW) signal modulated with a low extinction-ratio external modulator. KCI Citation Count: 1
ISSN:0374-4884
1976-8524
DOI:10.3938/jkps.43.714