This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly...
Gespeichert in:
Veröffentlicht in: | 대한구강보건학회지 2024, 48(4), , pp.169-176 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | kor |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Objectives: This study aimed to evaluate the effect of different types and angulations of ultrasonic scaler tips on the surfaces of denture base resins.
Methods: Heat-polymerized and computer-aided design/computer-aided manufacturing (CAD/CAM) denture base resin specimens were manufactured in rectangular shapes (60×10×3 mm) and divided into four groups. Stainless-steel and carbon scaler tips were applied at angles of 0° and 45° with 100 g of weight for 60 seconds, and the depth and volume of the surface defects were compared.
Results: Stainless-steel tips with a 45° angle showed a larger defect depth and volume than stainless- steel tips with a 0° angle and carbon tips with a 0° angle (P |
---|---|