Evaluating the efficacy of a cost-effective, fully three-dimensional-printed vertebra model for endoscopic spine surgery training for neurosurgical residents
A fused deposition modeling three-dimensional (3D)-printed model of the L4-5 vertebra for lumbar discectomy was designed. The model included separately printed dura mater, spinal cord, ligamentum flavum, intervertebral disc (from thermoplastic polyurethane), and bony structures (from polylactic acid...
Gespeichert in:
Veröffentlicht in: | Asian spine journal 2024, 18(5), , pp.630-638 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A fused deposition modeling three-dimensional (3D)-printed model of the L4-5 vertebra for lumbar discectomy was designed. The model included separately printed dura mater, spinal cord, ligamentum flavum, intervertebral disc (from thermoplastic polyurethane), and bony structures (from polylactic acid), and the material cost approximately US$ 1 per model. A simple plumbing endoscope was used for visualization. Dura mater injury was assessed by painting two layers on the dura mater, which peeled off with trauma.
Endoscopic spine surgery is a subject of high interest in neurosurgery given its minimally invasive nature; however, it has a steep learning curve. This study evaluated the effectiveness of a cost-efficient 3D-printed model when teaching this technique to neurosurgery residents.
Only a few studies have investigated the efficacy of such a model.
Eight residents with >2 years of training participated. Residents performed the procedure bilaterally and twice at 1-week intervals.
From the 32 surgeries, four were excluded because of facet removal (as it widened the surgical corridor), leaving 28 surgeries for analysis. Initial surgeries demonstrated a mean operation time of 21 minutes 18 seconds (standard deviation [SD], 2 minutes 32 seconds), which improved to a mean of 6 minutes 45 seconds (SD, 37 seconds) in the fourth surgery (F(3, 17)=19.18, p |
---|---|
ISSN: | 1976-1902 1976-7846 |
DOI: | 10.31616/asj.2024.0288 |