Non-Contacting Finger Seal Developments and Design Considerations
A three dimensional Navier-Stokes based code (CFD-ACE+/FEMSTRESS) was utilized to analyze the thermofluid behavior of a modified FS. The pressure patterns, mass flows and load carrying capabilities of this structure were assessed. It was found that even at a lower linear velocity of 216mps (708 fps)...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A three dimensional Navier-Stokes based code (CFD-ACE+/FEMSTRESS) was utilized to analyze the thermofluid behavior of a modified FS. The pressure patterns, mass flows and load carrying capabilities of this structure were assessed. It was found that even at a lower linear velocity of 216mps (708 fps) the geometry proposed has good lifting capability. |
---|