Non-Contacting Finger Seal Developments and Design Considerations

A three dimensional Navier-Stokes based code (CFD-ACE+/FEMSTRESS) was utilized to analyze the thermofluid behavior of a modified FS. The pressure patterns, mass flows and load carrying capabilities of this structure were assessed. It was found that even at a lower linear velocity of 216mps (708 fps)...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Proctor, Margaret P., Braun, M. Jack, Pierson, Hazel M., Deng, Dingeng, Choy, Fred K.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A three dimensional Navier-Stokes based code (CFD-ACE+/FEMSTRESS) was utilized to analyze the thermofluid behavior of a modified FS. The pressure patterns, mass flows and load carrying capabilities of this structure were assessed. It was found that even at a lower linear velocity of 216mps (708 fps) the geometry proposed has good lifting capability.