Distortion in a full-scale bicone inlet with internal focused compression and 45 percent internal contraction
The distortion characteristics were investigated at the subsonic diffuser exit of a full-scale, Mach 2.5, axisymmetric, mixed compression inlet. Performance and steady-state distortion characteristics were obtained at zero and maximum angle of attack and during an inlet unstart-restart sequence. For...
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Report |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The distortion characteristics were investigated at the subsonic diffuser exit of a full-scale, Mach 2.5, axisymmetric, mixed compression inlet. Performance and steady-state distortion characteristics were obtained at zero and maximum angle of attack and during an inlet unstart-restart sequence. For the configuration with no cowl bleed, steady-state distortion P(max)P(min)P(bar) ranged from 0.10 for critical inlet operation at 0 deg angle-of-attack to 0.306 for supercritical inlet operation at 6.84 deg angle-of-attack. Vortex generators provided a 50 percent reduction in steady-state distortion for critical operation. Bleed has a smaller effect on steady-stated distortion. |
---|