Development and validation of a 3D anthropomorphic phantom for dental CBCT imaging research
BACKGROUND: Optimization of dental cone beam computed tomography (CBCT) imaging is still in a preliminary stage and should be addressed using task-based methods. Dedicated models containing relevant clinical tasks for image quality studies have yet to be developed. PURPOSE: To present a methodology...
Gespeichert in:
Veröffentlicht in: | MEDICAL PHYSICS 2023-11, Vol.50 (11), p.6714-6736 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | BACKGROUND: Optimization of dental cone beam computed tomography (CBCT) imaging is still in a preliminary stage and should be addressed using task-based methods. Dedicated models containing relevant clinical tasks for image quality studies have yet to be developed. PURPOSE: To present a methodology to develop and validate a virtual adult anthropomorphic voxel phantom for use in task-based image quality optimization studies in dental CBCT imaging research, focusing on root fracture (RF) detection tasks in the presence of metal artefacts. METHODS: The phantom was developed from a CBCT scan with an isotropic voxel size of 0.2 mm, from which the main dental structures, mandible and maxilla were segmented. The missing large anatomical structures, including the spine, skull and remaining soft tissues, were segmented from a lower resolution full skull scan. Anatomical abnormalities were absent in the areas of interest. Fine detailed dental structures, that could not be segmented due to the limited resolution and noise in the clinical data, were modelled using a-priori anatomical knowledge. Model resolution of the teeth was therefore increased to 0.05 mm. Models of RFs as well as dental restorations to create the artefacts, were developed, and could be inserted in the phantom in any desired configuration. Simulated CBCT images of the models were generated using a newly developed multi-resolution simulation framework that incorporated the geometry, beam quality, noise and spatial resolution characteristics of a real dental CBCT scanner. Ray-tracing and Monte Carlo techniques were used to create the projection images, which were reconstructed using the classical FDK algorithm. Validation of the models was assessed by measurements of different tooth lengths, the pulp volume and the mandible, and comparison with reference values. Additionally, the simulated images were used in a reader study in which two oral radiologists had to score the realism level of the model's normal anatomy, as well as the modelled RFs and restorations. RESULTS: A model of an adult head, as well as models of RFs and different types of dental restorations were created. Anatomical measurements were consistent with ranges reported in literature. For the tooth length measurements, the deviations from the mean reference values were less than 20%. In 77% of all the measurements, the deviations were within 10.1%. The pulp volumes, and mandible measurements were within one standard deviation of the re |
---|---|
ISSN: | 0094-2405 |