An Automated Toolbox to Predict Single Subject Atrophy in Presymptomatic Granulin Mutation Carriers

BACKGROUND: Magnetic resonance imaging (MRI) measures may be used as outcome markers in frontotemporal dementia (FTD). OBJECTIVES: To predict MRI cortical thickness (CT) at follow-up at the single subject level, using brain MRI acquired at baseline in preclinical FTD. METHODS: 84 presymptomatic subj...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JOURNAL OF ALZHEIMERS DISEASE 2022, Vol.86 (1), p.205-218
Hauptverfasser: Premi, Enrico, Costa, Tommaso, Gazzina, Stefano, Benussi, Alberto, Cauda, Franco, Gasparotti, Roberto, Archetti, Silvana, Alberici, Antonella, van Swieten, John C, Sanchez-Valle, Raquel, Moreno, Fermin, Santana, Isabel, Laforce, Robert, Ducharme, Simon, Graff, Caroline, Galimberti, Daniela, Masellis, Mario, Tartaglia, Carmela, Rowe, James B, Finger, Elizabeth, Tagliavini, Fabrizio, de Mendonca, Alexandre, Vandenberghe, Rik, Gerhard, Alexander, Butler, Chris R, Danek, Adrian, Synofzik, Matthis, Levin, Johannes, Otto, Markus, Ghidoni, Roberta, Frisoni, Giovanni, Sorbi, Sandro, Peakman, Georgia, Todd, Emily, Bocchetta, Martina, Rohrer, Johnathan D, Borroni, Barbara
Format: Artikel
Sprache:eng
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:BACKGROUND: Magnetic resonance imaging (MRI) measures may be used as outcome markers in frontotemporal dementia (FTD). OBJECTIVES: To predict MRI cortical thickness (CT) at follow-up at the single subject level, using brain MRI acquired at baseline in preclinical FTD. METHODS: 84 presymptomatic subjects carrying Granulin mutations underwent MRI scans at baseline and at follow-up (31.2±16.5 months). Multivariate nonlinear mixed-effects model was used for estimating individualized CT at follow-up based on baseline MRI data. The automated user-friendly preGRN-MRI script was coded. RESULTS: Prediction accuracy was high for each considered brain region (i.e., prefrontal region, real CT at follow-up versus predicted CT at follow-up, mean error ≤1.87%). The sample size required to detect a reduction in decline in a 1-year clinical trial was equal to 52 subjects (power = 0.80, alpha = 0.05). CONCLUSION: The preGRN-MRI tool, using baseline MRI measures, was able to predict the expected MRI atrophy at follow-up in presymptomatic subjects carrying GRN mutations with good performances. This tool could be useful in clinical trials, where deviation of CT from the predicted model may be considered an effect of the intervention itself.
ISSN:1387-2877