Influence of basis images and skull position on evaluation of cortical bone thickness in cone beam computed tomography
The aim of this study was to assess the influence of the number of basis images and the orientation of the skull on the evaluation of cortical alveolar bone in cone beam computed tomography (CBCT).
Gespeichert in:
Veröffentlicht in: | Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology Oral Medicine, Oral Pathology and Oral Radiology, 2017, Vol.123 (6), p.707-713 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of this study was to assess the influence of the number of basis images and the orientation of the skull on the evaluation of cortical alveolar bone in cone beam computed tomography (CBCT). |
---|---|