삼차원 자기공명영상법의 뇌 구조 영상을 위한 최적화 연구: 센스인자 변화에 따른 신호변화 평가
Purpose : A parallel imaging method provides us to improve temporal resolution to obtain three-dimensional (3D) MR images. The objective of this study was to optimize three 3D MRI techniques by adjusting 2D SESNE factors of the parallel imaging method in phantom and human brain. Materials and Method...
Gespeichert in:
Veröffentlicht in: | Taehan Chagi Kongmyŏng Ŭikwa Hakhoe chi 2009, Vol.13 (2), p.161-170 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | kor |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose : A parallel imaging method provides us to improve temporal resolution to obtain three-dimensional (3D) MR images. The objective of this study was to optimize three 3D MRI techniques by adjusting 2D SESNE factors of the parallel imaging method in phantom and human brain. Materials and Methods : With a 3 Tesla MRI system and an 8-channel phase-array sensitivity-encoding (SENSE) coil, three 3D MRI techniques of 3D T1-weighted imaging (3D T1WI), 3D T2-weighted imaging (3D T2WI) and 3D fluid attenuated inversion recovery (3D FLAIR) imaging were optimized with adjusting SESNE factors in a water phantom and three human brains. The 2D SENSE factor was applied on the phase-encoding and the slice-encoding directions. Signal-to-noise ratio(SNR), percent signal reduction rate(%R), and contrast-to-noise ratio(CNR) were calculated by using signal intensities obtained in specific regions-of-interest (ROI). Results : In the phantom study, SENSE factor = 3 was provided in 0.2% reduction of signals against without using SENSE with imaging within 5 minutes for 3D T1WI. SENSE factor = 2 was provided in 0.98% signal reduction against without using SENSE with imaging within 5 minutes for 3D T2WI. SENSE factor = 4 was provided in 0.2% signal reduction against without using SENSE with imaging around 6 minutes for 3D FLAIR. In the human brain study, SNR and CNR were higher with SENSE factors = 3 than 4 for all three imaging techniques. Conclusion : This study was performed to optimize 2D SENSE factors in the three 3D MRI techniques that can be scanned in clinical time limitations with minimizing SNR reductions. Without compromising SNR and CNR, the optimum 2D SENSE factors were 3 and 4, yielding the scan time of about 5 to 6 minutes. Further studies are necessary to optimize 3D MRI techniques in other areas in human body. 목적 : 평행영상(Parallel imaging)기법의 개발로 긴 촬영시간 때문에 종종 사용되지 못하던 삼차원 영상기법이 최근 들어 환자 병을 진단하는데 새로이 사용되고 있다. 이 연구의 목적은 최근에 뇌 영상에서 개발되어 이용되고 있는 삼차원 자기공명영상을 사람의 뇌에서 짧은 시간 내에 얻을 수 있도록 2차원 평행영상 기법을 사용한 최적화 방법을 연구하는데 있다. 대상 및 방법 : 검사 장비는 3.0T 자기공명영상장치를 이용하였으며 8-채널 SENSE(sensitivity encoding) 머리 코일을 이용하였다. 팬텀 및 3명의 사람 머리에서 영상을 얻었다. 세 가지의 삼차원 영상법인 3D T1WI, 3D T2WI 및 3D FLAIR 영상 방법에 대하여 평행인자(SENSE factor)의 변화에 따른 팬텀 영상을 얻었다. 각각의 영상법에서 영상획득에 적당한 SENSE 인자를 찾기 위해 Phase encoding 방향과 Slice encoding 방향을 조합한 SENSE 인자를 변화시키면서 영상을 얻었다. 영상분석을 위하여 특정영역(ROI)를 설정한 후에 신호대 잡음비 (Signal-to-noise ratio, SNR), 감소분율(Percent Signal Reduction Rate, %R), 대조도(contrast-to-noise ratio, CNR)를 계산하였다 |
---|---|
ISSN: | 1226-9751 2288-3800 |