국소 간병변 감별에서 단발고속스핀에코 기법과 균형항정상 태세차를 이용한 고속영역 기법간의 비교
Purpose : To determine the diagnostic accuracy of four different sequences : moderately T2 weighted, two heavily T2-weighted single shot turbo spin-echo sequence and breath-hold axial-2D balanced turbo field-echo sequence(bFFE) for characterization of focal lesions. Materials and Methods : During th...
Gespeichert in:
Veröffentlicht in: | Taehan Chagi Kongmyŏng Ŭikwa Hakhoe chi 2007, Vol.11 (1), p.39-48 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | kor |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose : To determine the diagnostic accuracy of four different sequences : moderately T2 weighted, two heavily T2-weighted single shot turbo spin-echo sequence and breath-hold axial-2D balanced turbo field-echo sequence(bFFE) for characterization of focal lesions. Materials and Methods : During the 3-month period between June and August 2005, seventy-six patients were proved to have ninety-three focal hepatic lesions on MR imaging. The patients consisted of 49 men and 27 women (age range, 15-75 years; mean age, 56.23 years). All MR images were acquired on a 1.5-T MR using the following sequences: 1. A breath-hold axial T2-weighted single shot turbo spin-echo sequence, 2. a breath-hold axial-2D balanced turbo field-echo sequence. Two radiologists performed quantitative analysis. Another radiologist measured the lesion-to-liver contrast-to-noise ratio at the region-of-interest in the four sequences. Results : There was no significant difference in inter-observer variability between the four sequences. The accuracy for both cyst and malignancy of moderate T2 weighted MRI (echo time: 80 msec) was also highest. There was significant difference for lesion characterization between moderate T2 weighted MRI and balanced steady state procession (p-value: 0.004) in the second reader. For longer echo time, the CNR of cystic lesions were markedly increased in comparison to lesions of other component. Conclusion : The accuracy and inter-observer variability of single shot turbo spin echo T2 weighted sequence was higher than bFFE. Although there was no statically significant difference, moderate T2 weighted MRI (echo time: 80 msec) was more accurate than heavily T2 weighted sequence (echo time: 300 msec). If the results for lesion characterization is equivocal in TE 80, the addition of heavily T2 weighted MRI (echo time: 180 msec) can be helpful. 목적 : 다양한 강한 T2 고속 스핀 에코 기법과 균형항정상태세차를 이용한 고속 영상 기법을 이용하여 국소 간병변 진단시 낭성 여부를 평가하고 악성 여부를 진단하는데 4가지 기법간의 유의한 차이가 있는지를 알아보고자 하였다. 대상 및 방법 : 2005년 6월부터 8월까지 76명의 환자에서 자기공영상에서 확인된 93예의 국소 간 병변을 대상으로 하였다. 초전도형 1.5T 자기 공명 영상 장치를 이용 세가지 다른 에코시간(80, 180-190, 300 msec)의 호흡 중지 T2강조 단발 고속 스핀 에코 촬영 기법과 호흡 중지 2차원 균형항정상태세차를 이용한 기법의 고속 영상 기법으로 시행되었다. 2명의 방사선과 전문의가 정성적 분석하였다. 그리고, 또 다른 방사선과 전문의가 병변 대 병변 대간 대조대잡음비를 구하였다. 결과 : 네 가지 기법에서 판독자간의 일치도는 낭성 평가와 악성도 평가에서 통계적으로 유의한 차이는 보이지 않았다. 낭성 그리고 악성도 평가의 정확도는 에코시간 80 msec에서 가장 높았다. 악성도 평가시 제 2 판독자에서 에코시간 80 msec과 균형항정상태세차간에 p-값이 0.004로 통계적으로 유의한 차이를 보였다. 병변 대 간 대조대잡음비를 구하였고 에코시간이 길어질수록 낭성 병변의 대조대잡음비는 |
---|---|
ISSN: | 1226-9751 2288-3800 |