수종의 NiTi 전동 파일 단면 형태 비교 및 pecking motion의 사용방법이 피로 파절에 미치는 영향
There are various factors affecting the fracture of NiTi rotary files. This study was performed to evaluate the effect of cross sectional area, pecking motion and pecking distance on the cyclic fatigue fracture of different NiTi files. Five different NiTi $files-Profile^{(R)}$ (Maillefer, Ballaigue,...
Gespeichert in:
Veröffentlicht in: | 大韓齒科保存學會誌 2006, Vol.31 (2), p.96-102 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | kor |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | There are various factors affecting the fracture of NiTi rotary files. This study was performed to evaluate the effect of cross sectional area, pecking motion and pecking distance on the cyclic fatigue fracture of different NiTi files. Five different NiTi $files-Profile^{(R)}$ (Maillefer, Ballaigue, Switzerland), $ProTaper^{TM}$(Maillefer, Ballaigue, Switzerland), $K3^{(R)}$ (SybronEndo. Orange, CA) , Hero $642^{(R)}$ (Micro-mega, Besancon, France), Hero $Shaper^{(R)}$ (Micro-mega, Besancon, France)-were used. Each file was embedded in temporary resin, sectioned horizontally and observed with scanning electron microscope. The ratio of cross-sectional area to the circumscribed circle was calculated. Special device was fabricated to simulate the cyclic fatigue fracture of NiTi file in the curved canal,. On this device, NiTi files were rotated (300rpm) with different pecking distances (3 mm or 6 mm) and with different motions (static motion or dynamic pecking motion) . Time until fracture occurs was measured. The results demonstrated that cross-sectional area didn't have any effect on the time of file fracture. Among the files, $Profile^{(R)}$ took the longest time to be fractured. Between the pecking motions, dynamic motion took the longer time to be fractured than static motion. There was no significant difference between the pecking distances with dynamic motion, however with static motion, the longer time was taken at 3mm distance. In this study, we could suggest that dynamic pecking motion would lengthen the time for NiTi file to be fractured from cyclic fatigue. 본 연구는 현재 시판중인 $Profile^{(R)},\;ProTaper^{(R)},\;K3^{(R)},\;Hero\;642^{(R)},\;Hero\;Shaper^{(R)}$를 단면을 비교하고 이들 5가지 NiTi 파일과 사용방법에 따른 피로 파절 소요 시간을 비교하고자 시행되었다. 각 NiTi전동파일의 치근단 1/3을 temporary resin에 매몰시키고 다이아몬드 표면처리된 버로 잘라내어, 초음파를 이용하여 세척 후, 주사전자현미경으로 단면을 관찰하였다. 주기적인 피로 실험을 수행하기 위해, 회전속도, pecking 거리를 자동적으로 조절할 수 있는 장치를 제작하고 파일을 만곡된 상태를 재현하기 위하여 15도 경사진 금속 토막에 위치시키고 분당 300회전의 속도로 회전시켜 파일이 파절될 때까지의 시간을 측정하였다. 사용방법에 따른 실험군은 동적군과 정적군으로 나누고 pecking 거리는 3 mm, 6 mm로 하였다. 실험결과 동적군 보다는 정적군의 피로파절 소요시간이 통계학적으로 유의차 있게 짧았으며 3 mm, 6 mm의 pecking distance에 따른 영향은 나타나지 않았다. 결론적으로 NiTi전동파일은 pecking motion으로 사용하는 것이 피로파절을 줄이는데 도움이 될 것으로 사료된다. |
---|---|
ISSN: | 1225-0864 |