Postoperative Severity Assessment in Sheep

Introduction: Sheep are frequently used in translational surgical orthopedic studies. Naturally, a good pain management is mandatory for animal welfare, although it is also important with regard to data quality. However, methods for adequate severity assessment, especially considering pain, are rath...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European surgical research 2023, Vol.64 (1), p.27-36
Hauptverfasser: Zentrich, Eva, Wassermann, Laura, Struve, Birgitta, Selke, Kristin, Buettner, Manuela, Keubler, Lydia Maria, Reifenrath, Janin, Angrisani, Nina, Kempfert, Merle, Krause, Annika, Bellmann, Olaf, Kopaczka, Marcin, Merhof, Dorit, Bankstahl, Marion, Bleich, André, Häger, Christine
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction: Sheep are frequently used in translational surgical orthopedic studies. Naturally, a good pain management is mandatory for animal welfare, although it is also important with regard to data quality. However, methods for adequate severity assessment, especially considering pain, are rather rare regarding large animal models. Therefore, in the present study, accompanying a surgical pilot study, telemetry and the Sheep Grimace Scale (SGS) were used in addition to clinical scoring for severity assessment after surgical interventions in sheep. Methods: Telemetric devices were implanted in a first surgery subcutaneously into four German black-headed mutton ewes (4–5 years, 77–115 kg). After 3–4 weeks of recovery, sheep underwent tendon ablation of the left M. infraspinatus. Clinical scoring and video recordings for SGS analysis were performed after both surgeries, and the heart rate (HR) and general activity were monitored by telemetry. Results: Immediately after surgery, clinical score and HR were slightly increased, and activity was decreased in individual sheep after both surgeries. The SGS mildly elevated directly after transmitter implantation but increased to higher levels after tendon ablation immediately after surgery and on the following day. Conclusion: In summary, SGS- and telemetry-derived data were suitable to detect postoperative pain in sheep with the potential to improve individual pain recognition and postoperative management, which consequently contributes to refinement.
ISSN:0014-312X
1421-9921
DOI:10.1159/000526058