Clinical Utility of the Electrocardiographic P-Wave Axis in Patients with Chronic Obstructive Pulmonary Disease

Background: The vertical P-wave axis on electrocardiography (ECG) is a useful criterion for screening patients with chronic obstructive pulmonary disease (COPD). This study aimed to investigate the clinical characteristics of patients with COPD with a vertical P-wave axis as they have not yet been e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Respiration 2022-04, Vol.101 (4), p.345-352
Hauptverfasser: Otake, Shiro, Chubachi, Shotaro, Nakayama, Shingo, Sakurai, Kaori, Irie, Hidehiro, Hashiguchi, Mizuha, Itabashi, Yuji, Yamada, Yoshitake, Jinzaki, Masahiro, Murata, Mitsuru, Nakamura, Hidetoshi, Asano, Koichiro, Fukunaga, Koichi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background: The vertical P-wave axis on electrocardiography (ECG) is a useful criterion for screening patients with chronic obstructive pulmonary disease (COPD). This study aimed to investigate the clinical characteristics of patients with COPD with a vertical P-wave axis as they have not yet been elucidated. Methods: Keio University and its affiliated hospitals conducted an observational COPD cohort study over 3 years. We analyzed 201 patients using ECG and chest computed tomography. Results: The severity of airflow limitation was higher in patients with a P-wave axis >75° than in those with a P-wave axis ≤75°. Patients with a P-wave axis >75° exhibited significantly higher total COPD assessment test scores and increased St. George’s Respiratory Questionnaire total, activity, and impact scores than those with a P-wave axis ≤75°. The incidence of exacerbations over 1 and 3 years was significantly higher in patients with a P-wave axis >75° than in those with a P-wave axis ≤75°. The optimal cutoff for the P-wave axis for a percentage of the predicted forced expiratory volume in 1 s 75° than in those with a P-wave axis ≤75°. However, the ratio of the airway wall area did not differ between the 2 groups. Conclusions: Patients with COPD with a vertical P-wave axis exhibited severe airflow limitation and emphysema, a worse health status, and more frequent exacerbation than patients without a vertical P-wave. Detection of the vertical P-wave axis by ECG is beneficial for the management of patients with COPD.
ISSN:0025-7931
1423-0356
DOI:10.1159/000519668