Development and Internal Validation of a Prediction Model to Estimate the Probability of Left-Ventricular Diastolic Dysfunction in Stable Maintenance Hemodialysis Patients without Clinical Heart Failure

Objective: To develop and internally validate a multivariable prediction model based on simple clinical record data and laboratory tests and to estimate the probability of left-ventricular diastolic dysfunction (LVDD) in stable maintenance hemodialysis (MHD) patients without clinical heart failure....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nephron (2015) 2019-01, Vol.142 (4), p.301-310
Hauptverfasser: Sun, Linlin, Ji, Yongqiang, Wang, Yanzhe, Zhu, Dingyu, Chen, Fuhua, Zhang, Nan, Shen, E, Wang, Xiaoxia
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective: To develop and internally validate a multivariable prediction model based on simple clinical record data and laboratory tests and to estimate the probability of left-ventricular diastolic dysfunction (LVDD) in stable maintenance hemodialysis (MHD) patients without clinical heart failure. Design: Cross-sectional study. Setting and Participants: In all, 181 patients on MHD without clinical heart failure were eligible from the dialysis center of Tongren Hospital, Shanghai Jiao Tong University School of Medicine between October 2017 and September 2018. Outcomes: LVDD detected by echocardiography. Measurements: We performed multivariable logistic regression using demographic, clinical, and laboratory data to identify predictors of LVDD with internal validation by using 200 bootstrap replications. Results: Overall, 78 out of 181 (43.1%) patients were affected by LVDD. Predictors included in the LVDD Model were high-sensitive cardiac troponin T (OR 5.91 per 1-ln unit; 95% CI 2.17–16.13), B-type natriuretic peptide (OR 2.35 per 1-ln unit; 95% CI 1.14–4.86), and dialysis vintage (OR 1.04 per 1-month; 95% CI 1.01–1.07). The area (AUC) under the receiver operating characteristic curve of the Model was 0.871 (95% CI 0.811–0.932, p < 0.001). The calibration plot showed good agreement between predicted and observed probabilities with a calibration slope of 1.023 and intercept of –0.010. After internal validation, the Model maintained excellent discrimination (AUC 0.858, 95% CI 0.798–0.919) and good calibration (slope of 1.079, 95% CI 1.058–1.097 and intercept of –0.120, 95% CI –0.142 to –0.093). LVDD Model
ISSN:1660-8151
2235-3186
DOI:10.1159/000499605