Exo-interferometric phase determination in nuclear resonant scattering
The time-dependent phase change of X-rays after transmission through a sample has been determined experimentally. We used an X-ray interferometer with a reference sample containing sharp nuclear resonances to prepare a phase-controlled X-ray beam. A sample with similar resonances was placed in the b...
Gespeichert in:
Veröffentlicht in: | Europhysics letters 2004-05, Vol.66 (4), p.506-512 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The time-dependent phase change of X-rays after transmission through a sample has been determined experimentally. We used an X-ray interferometer with a reference sample containing sharp nuclear resonances to prepare a phase-controlled X-ray beam. A sample with similar resonances was placed in the beam but outside of the interferometer; hence our use of the term “exo-interferometric”. We show that the phase change of the X-rays due to the sample can be uniquely determined from the time-dependent transmitted intensities. The energy response of the sample was reconstructed from the phase and the intensity data with a resolution of 23$\un{neV}$. |
---|---|
ISSN: | 0295-5075 1286-4854 |
DOI: | 10.1209/epl/i2003-10235-7 |