Stabilization of the emission frequency of an injection laser with an external resonator

Stabilization of the emission frequency of a tunable injection laser with an external resonator was achieved using a high-Q confocal interferometer. The emission frequency drift relative to a control interferometer did not exceed 1 MHz/min. The operating characteristics of the system were analyzed a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sov. J. Quant. Electron. (Engl. Transl.); (United States) 1982-04, Vol.12 (4), p.502-504, Article 502
Hauptverfasser: Zibrov, A S, Akul'shin, A M, Velichanskiĭ, V L, Malakhova, V I, Nikitin, V V, Sautenkov, V A, Tyurikov, D A, Yurkin, E K
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Stabilization of the emission frequency of a tunable injection laser with an external resonator was achieved using a high-Q confocal interferometer. The emission frequency drift relative to a control interferometer did not exceed 1 MHz/min. The operating characteristics of the system were analyzed and possible applications were considered.
ISSN:0049-1748
2169-530X
DOI:10.1070/QE1982v012n04ABEH012348