Development of accurate two-dimensional dose-imaging detectors using atomic-scale color centers in Ag-activated phosphate glass and LiF thin films
Novel disk-type X-ray two-dimensional (2D) imaging detectors have been developed by utilising atomic-scale defects as minimum luminescent units such as radiation-induced Ag-related species in Ag-activated phosphate glass and F-aggregated centres in lithium fluoride (LiF) thin films. Such luminescent...
Gespeichert in:
Veröffentlicht in: | Japanese Journal of Applied Physics 2014-02, Vol.53 (2S), p.2-1-02BD14-5 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1-02BD14-5 |
---|---|
container_issue | 2S |
container_start_page | 2 |
container_title | Japanese Journal of Applied Physics |
container_volume | 53 |
creator | Kurobori, Toshio Matoba, Akinari |
description | Novel disk-type X-ray two-dimensional (2D) imaging detectors have been developed by utilising atomic-scale defects as minimum luminescent units such as radiation-induced Ag-related species in Ag-activated phosphate glass and F-aggregated centres in lithium fluoride (LiF) thin films. Such luminescent detectors are based on the radiophotoluminescence (RPL) and photoluminescence (PL) phenomena, respectively. Accurate accumulated 2D dose distributions with a high spatial resolution of micron order over large areas and a wide dynamic range covering 8 orders of magnitude were rapidly reconstructed and were successfully demonstrated for the first time by combining the Ag-doped glass with LiF thin films. These detectors should be suitable for X- and gamma-ray imaging in radiation diagnostics and clinical radiotherapy. |
doi_str_mv | 10.7567/JJAP.53.02BD14 |
format | Article |
fullrecord | <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_iop_journals_10_7567_JJAP_53_02BD14</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1685763043</sourcerecordid><originalsourceid>FETCH-LOGICAL-c407t-80f93e0a4a6642f32c35b9f16a2bce84e5917186f7ef3cc5bea6a37b10cc369f3</originalsourceid><addsrcrecordid>eNp1kE1vEzEQhi1EJULLlbOPgORgrz82ewwtBapIVCqcLcc7Thx514vtbcXf4BfjVXqE02hGz7wzehB6y-i6lar9eHe3vV9LvqbNpxsmXqAV46Ilgir5Eq0obRgRXdO8Qq9zPtVWScFW6M8NPEKI0wBjwdFhY-2cTAFcniLpfR1nH0cTcB8zED-Ygx8PuIcCtsSU8ZyX3pQ4eEuyNQGwjSEmbGsgVMCPeHsgxhb_WGN7PB1jno7LhUMwOWMz9njnb3E5VtL5MOQrdOFMyPDmuV6in7eff1x_JbvvX75db3fECtoWsqGu40CNMEqJxvHGcrnvHFOm2VvYCJAda9lGuRYct1buwSjD2z2j1nLVOX6J3p1zpxR_zZCLHny2EIIZIc5ZM7WRreJU8Iquz6hNMecETk-puki_NaN6ka8X-VpyfZZfF96fF3yc9CnOqSrM-nQy0wI1D8-cnvrljw__YP8T_BecU5YF</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1685763043</pqid></control><display><type>article</type><title>Development of accurate two-dimensional dose-imaging detectors using atomic-scale color centers in Ag-activated phosphate glass and LiF thin films</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Kurobori, Toshio ; Matoba, Akinari</creator><creatorcontrib>Kurobori, Toshio ; Matoba, Akinari</creatorcontrib><description>Novel disk-type X-ray two-dimensional (2D) imaging detectors have been developed by utilising atomic-scale defects as minimum luminescent units such as radiation-induced Ag-related species in Ag-activated phosphate glass and F-aggregated centres in lithium fluoride (LiF) thin films. Such luminescent detectors are based on the radiophotoluminescence (RPL) and photoluminescence (PL) phenomena, respectively. Accurate accumulated 2D dose distributions with a high spatial resolution of micron order over large areas and a wide dynamic range covering 8 orders of magnitude were rapidly reconstructed and were successfully demonstrated for the first time by combining the Ag-doped glass with LiF thin films. These detectors should be suitable for X- and gamma-ray imaging in radiation diagnostics and clinical radiotherapy.</description><identifier>ISSN: 0021-4922</identifier><identifier>EISSN: 1347-4065</identifier><identifier>DOI: 10.7567/JJAP.53.02BD14</identifier><identifier>CODEN: JJAPB6</identifier><language>eng</language><publisher>The Japan Society of Applied Physics</publisher><subject>Color centers ; Detectors ; Diagnostic systems ; Dynamic range ; Imaging ; Phosphate glass ; Silver ; Thin films ; Two dimensional</subject><ispartof>Japanese Journal of Applied Physics, 2014-02, Vol.53 (2S), p.2-1-02BD14-5</ispartof><rights>2014 The Japan Society of Applied Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c407t-80f93e0a4a6642f32c35b9f16a2bce84e5917186f7ef3cc5bea6a37b10cc369f3</citedby><cites>FETCH-LOGICAL-c407t-80f93e0a4a6642f32c35b9f16a2bce84e5917186f7ef3cc5bea6a37b10cc369f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.7567/JJAP.53.02BD14/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,780,784,27924,27925,53846,53893</link.rule.ids></links><search><creatorcontrib>Kurobori, Toshio</creatorcontrib><creatorcontrib>Matoba, Akinari</creatorcontrib><title>Development of accurate two-dimensional dose-imaging detectors using atomic-scale color centers in Ag-activated phosphate glass and LiF thin films</title><title>Japanese Journal of Applied Physics</title><addtitle>Jpn. J. Appl. Phys</addtitle><description>Novel disk-type X-ray two-dimensional (2D) imaging detectors have been developed by utilising atomic-scale defects as minimum luminescent units such as radiation-induced Ag-related species in Ag-activated phosphate glass and F-aggregated centres in lithium fluoride (LiF) thin films. Such luminescent detectors are based on the radiophotoluminescence (RPL) and photoluminescence (PL) phenomena, respectively. Accurate accumulated 2D dose distributions with a high spatial resolution of micron order over large areas and a wide dynamic range covering 8 orders of magnitude were rapidly reconstructed and were successfully demonstrated for the first time by combining the Ag-doped glass with LiF thin films. These detectors should be suitable for X- and gamma-ray imaging in radiation diagnostics and clinical radiotherapy.</description><subject>Color centers</subject><subject>Detectors</subject><subject>Diagnostic systems</subject><subject>Dynamic range</subject><subject>Imaging</subject><subject>Phosphate glass</subject><subject>Silver</subject><subject>Thin films</subject><subject>Two dimensional</subject><issn>0021-4922</issn><issn>1347-4065</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNp1kE1vEzEQhi1EJULLlbOPgORgrz82ewwtBapIVCqcLcc7Thx514vtbcXf4BfjVXqE02hGz7wzehB6y-i6lar9eHe3vV9LvqbNpxsmXqAV46Ilgir5Eq0obRgRXdO8Qq9zPtVWScFW6M8NPEKI0wBjwdFhY-2cTAFcniLpfR1nH0cTcB8zED-Ygx8PuIcCtsSU8ZyX3pQ4eEuyNQGwjSEmbGsgVMCPeHsgxhb_WGN7PB1jno7LhUMwOWMz9njnb3E5VtL5MOQrdOFMyPDmuV6in7eff1x_JbvvX75db3fECtoWsqGu40CNMEqJxvHGcrnvHFOm2VvYCJAda9lGuRYct1buwSjD2z2j1nLVOX6J3p1zpxR_zZCLHny2EIIZIc5ZM7WRreJU8Iquz6hNMecETk-puki_NaN6ka8X-VpyfZZfF96fF3yc9CnOqSrM-nQy0wI1D8-cnvrljw__YP8T_BecU5YF</recordid><startdate>20140201</startdate><enddate>20140201</enddate><creator>Kurobori, Toshio</creator><creator>Matoba, Akinari</creator><general>The Japan Society of Applied Physics</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20140201</creationdate><title>Development of accurate two-dimensional dose-imaging detectors using atomic-scale color centers in Ag-activated phosphate glass and LiF thin films</title><author>Kurobori, Toshio ; Matoba, Akinari</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c407t-80f93e0a4a6642f32c35b9f16a2bce84e5917186f7ef3cc5bea6a37b10cc369f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Color centers</topic><topic>Detectors</topic><topic>Diagnostic systems</topic><topic>Dynamic range</topic><topic>Imaging</topic><topic>Phosphate glass</topic><topic>Silver</topic><topic>Thin films</topic><topic>Two dimensional</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kurobori, Toshio</creatorcontrib><creatorcontrib>Matoba, Akinari</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Japanese Journal of Applied Physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kurobori, Toshio</au><au>Matoba, Akinari</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of accurate two-dimensional dose-imaging detectors using atomic-scale color centers in Ag-activated phosphate glass and LiF thin films</atitle><jtitle>Japanese Journal of Applied Physics</jtitle><addtitle>Jpn. J. Appl. Phys</addtitle><date>2014-02-01</date><risdate>2014</risdate><volume>53</volume><issue>2S</issue><spage>2</spage><epage>1-02BD14-5</epage><pages>2-1-02BD14-5</pages><issn>0021-4922</issn><eissn>1347-4065</eissn><coden>JJAPB6</coden><abstract>Novel disk-type X-ray two-dimensional (2D) imaging detectors have been developed by utilising atomic-scale defects as minimum luminescent units such as radiation-induced Ag-related species in Ag-activated phosphate glass and F-aggregated centres in lithium fluoride (LiF) thin films. Such luminescent detectors are based on the radiophotoluminescence (RPL) and photoluminescence (PL) phenomena, respectively. Accurate accumulated 2D dose distributions with a high spatial resolution of micron order over large areas and a wide dynamic range covering 8 orders of magnitude were rapidly reconstructed and were successfully demonstrated for the first time by combining the Ag-doped glass with LiF thin films. These detectors should be suitable for X- and gamma-ray imaging in radiation diagnostics and clinical radiotherapy.</abstract><pub>The Japan Society of Applied Physics</pub><doi>10.7567/JJAP.53.02BD14</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-4922 |
ispartof | Japanese Journal of Applied Physics, 2014-02, Vol.53 (2S), p.2-1-02BD14-5 |
issn | 0021-4922 1347-4065 |
language | eng |
recordid | cdi_iop_journals_10_7567_JJAP_53_02BD14 |
source | IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link |
subjects | Color centers Detectors Diagnostic systems Dynamic range Imaging Phosphate glass Silver Thin films Two dimensional |
title | Development of accurate two-dimensional dose-imaging detectors using atomic-scale color centers in Ag-activated phosphate glass and LiF thin films |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T05%3A59%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20accurate%20two-dimensional%20dose-imaging%20detectors%20using%20atomic-scale%20color%20centers%20in%20Ag-activated%20phosphate%20glass%20and%20LiF%20thin%20films&rft.jtitle=Japanese%20Journal%20of%20Applied%20Physics&rft.au=Kurobori,%20Toshio&rft.date=2014-02-01&rft.volume=53&rft.issue=2S&rft.spage=2&rft.epage=1-02BD14-5&rft.pages=2-1-02BD14-5&rft.issn=0021-4922&rft.eissn=1347-4065&rft.coden=JJAPB6&rft_id=info:doi/10.7567/JJAP.53.02BD14&rft_dat=%3Cproquest_iop_j%3E1685763043%3C/proquest_iop_j%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1685763043&rft_id=info:pmid/&rfr_iscdi=true |