Actual defect observation results of an extreme-ultraviolet blank mask by coherent diffraction imaging

Extreme-ultraviolet (EUV) lithography poses a number of challenges, one of which is the production of a defect-free mask. To observe the defects on an EUV mask in a quantitative phase image, we have developed a microcoherent EUV scatterometry microscope. The intensity and phase images of the defects...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied physics express 2016-03, Vol.9 (3), p.35202
Hauptverfasser: Harada, Tetsuo, Hashimoto, Hiraku, Amano, Tsuyoshi, Kinoshita, Hiroo, Watanabe, Takeo
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Extreme-ultraviolet (EUV) lithography poses a number of challenges, one of which is the production of a defect-free mask. To observe the defects on an EUV mask in a quantitative phase image, we have developed a microcoherent EUV scatterometry microscope. The intensity and phase images of the defects are reconstructed using ptychography. We observe four actual defects on an EUV blank mask using the microscope. The reconstructed shapes of the actual defects correspond well to those measured by atomic force microscopy (AFM). Our microscope should therefore function as an essential review tool in characterizing defects.
ISSN:1882-0778
1882-0786
DOI:10.7567/APEX.9.035202