Wet etching and passivation of GaSb-based very long wavelength infrared detectors

The etching and passivation processes of very long wavelength infrared (VLWIR) detector based on the InAs/GaSb/AlSb type-II superlattice have been studied. By studying the effect of each component in the citric acid solution (citric acid, phosphoric acid, hydrogen peroxide, deionized water), the bes...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chinese physics B 2022-05, Vol.31 (6), p.68503-153
Hauptverfasser: Xu, Xue-Yue, Jiang, Jun-Kai, Chen, Wei-Qiang, Cui, Su-Ning, Zhou, Wen-Guang, Li, Nong, Chang, Fa-Ran, Wang, Guo-Wei, Xu, Ying-Qiang, Jiang, Dong-Wei, Wu, Dong-Hai, Hao, Hong-Yue, Niu, Zhi-Chuan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The etching and passivation processes of very long wavelength infrared (VLWIR) detector based on the InAs/GaSb/AlSb type-II superlattice have been studied. By studying the effect of each component in the citric acid solution (citric acid, phosphoric acid, hydrogen peroxide, deionized water), the best solution ratio is obtained. After comparing different passivation materials such as sulfide + SiO 2 , Al 2 O 3 , Si 3 N 4 and SU8, it is found that SU8 passivation can reduce the dark current of the device to a greater degree. Combining this wet etching and SU8 passivation, the R 0 A of VLWIR detector with a mesa diameter of 500 μm is about 3.6 Ω⋅cm 2 at 77 K.
ISSN:1674-1056
DOI:10.1088/1674-1056/ac4cc1