Measurement of gas holdup characteristics in two-phase column flotation by electrical capacitance volume tomography
Electrical capacitance volume tomography measured the gas holdup in two-phase column flotation. The purpose was to characterize gas holdup and understand its relation to flow patterns as a function of the types and doses of frothers. Experiments were conducted using laboratory-scale column flotation...
Gespeichert in:
Veröffentlicht in: | Physica scripta 2023-11, Vol.98 (11), p.115033 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Electrical capacitance volume tomography measured the gas holdup in two-phase column flotation. The purpose was to characterize gas holdup and understand its relation to flow patterns as a function of the types and doses of frothers. Experiments were conducted using laboratory-scale column flotation cells with dimensions of 5 ×125 cm. The superficial gas velocities in the experiment were 0.5–4 cm s
−1
with an interval of 0.5 cm/s. Methyl isobutyl carbinol (MIBC) and Oreprep F-583-OZ (Oreprep) were used as frothers at 5–40 ppm doses. The results showed that the difference between the lowest and highest gas holdup in the bubbly flow regime was ∼0.07, and the transition from the bubbly to churn-turbulent flow occurred at a superficial gas velocity of 2 c m /s . |
---|---|
ISSN: | 0031-8949 1402-4896 |
DOI: | 10.1088/1402-4896/ad008a |