Online Conductivity Monitoring of Dialysis Adequacy Versus Kt V Derived from Urea Reduction Ratio: A Prospective Study from a Saudi Center

Introduction. Adequate delivered dose of solute removal (as assessed by urea reduction and calculation of Kt V) is an important determinant of clinical outcome in chronic hemodialysis (HD) patients. This requires both prescription of an adequate dose of HD and regular assessment that the delivered t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Renal failure 2010-02, Vol.32 (1), p.36-40
Hauptverfasser: Al Saran, Khalid, Sabry, Alaa, Abdulghafour, Mamdouh, Yehia, Ahmed
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction. Adequate delivered dose of solute removal (as assessed by urea reduction and calculation of Kt V) is an important determinant of clinical outcome in chronic hemodialysis (HD) patients. This requires both prescription of an adequate dose of HD and regular assessment that the delivered treatments are also adequate. Online conductivity monitoring (OCM) using sodium flux as a surrogate for urea allows for the repeated non-invasive measurement of Kt V on each HD treatment. Methods. We prospectively studied 17 (9 males, 8 females) established chronic HD patients over an eight-week period (408 treatments). A pre- and post-dialyzer measurement of the conductivity is performed by two mutually independent temperature-compensated conductivity cells equipped with Fresenius 4008 S® dialysis machines. Urea reduction was measured once a week by a single-pool calculation using immediate post-treatment sampling. No changes were made to any of the dialysis prescriptions over the study period. Values of calculated Kt V and simultaneously obtained online Kt V were compared. Results. There was a statistically significant difference between calculated Kt V and online Kt V over the study period. The mean calculated Kt V was 1.37 ± 0.09, and mean online Kt V 1.02 ± 0.15 (p = 0.000). Calculated Kt V ≥ 1.2 was achieved in all our patients, while online Kt V ≥ 1.2 was achieved in only 17.64%. Yet there was moderate correlation between calculated Kt V and online Kt V (r2 = 0.48). Conclusions. Online conductivity monitoring (OCM) results underestimates dialysis efficiency compared to calculated Kt V readings. This difference has to be considered when applying Kt V to clinical practice.
ISSN:0886-022X
1525-6049
DOI:10.3109/08860220903367486