Volumetric analysis of epilepsy surgery resections using high resolution magnetic imaging: Technical report

A method is described for accurately measuring the volume and site of epilepsy surgery resections utilizing magnetic resonance imaging. Accuracy has been assessed using post-mortem studies, and both the intra- and interobserver variability is consistently less than 5%. The technique has so far been...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:British journal of neurosurgery 1993, Vol.7 (6), p.651-656
Hauptverfasser: Kitchen, Neil D., Thomas, David G. T., Shorvon, Simon D., Fish, David R., Stevens, John M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A method is described for accurately measuring the volume and site of epilepsy surgery resections utilizing magnetic resonance imaging. Accuracy has been assessed using post-mortem studies, and both the intra- and interobserver variability is consistently less than 5%. The technique has so far been applied to 25 patients following a variety of operations for medically intractable epilepsy. It provides the crucially accurate baseline required for meaningful follow-up outcome studies of epilepsy surgery. Consequently, it should allow the development of more precise prognostic indices for such operations.
ISSN:0268-8697
1360-046X
DOI:10.3109/02688699308995094