An Air-Equivalent Ionization Chamber
The characteristics of an air-equivalent ionization chamber used for routine exposure measurements were investigated. The air-equivalent material used was a mixture of 91% polycarbonate [(C 16 H 14 O 3 ) n ] and 9% E-glass (54% SiO 2 ; 1% Fe 2 O 3 ; 1% Na 2 O 2 + K 2 O 2 ; 1% TiO 2 ; 15% CaO; 8% B 2...
Gespeichert in:
Veröffentlicht in: | Isotopenpraxis 1989-01, Vol.25 (5), p.205-208 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The characteristics of an air-equivalent ionization chamber used for routine exposure measurements were investigated. The air-equivalent material used was a mixture of 91% polycarbonate [(C
16
H
14
O
3
)
n
] and 9% E-glass (54% SiO
2
; 1% Fe
2
O
3
; 1% Na
2
O
2
+ K
2
O
2
; 1% TiO
2
; 15% CaO; 8% B
2
O
3
). This is equivalent to a mixture of commercial thermoplastics consisting of 55% Makrolon-3100 natural and 45% Makrolon-8020 natural (Bayer). The parts of this chamber have been injection moulded and the chamber had volume of 1l and wall thickness of 2 mm. The inner surfaces of the chamber were coated with a conductive air-equivalent layer. The response of the chamber was slightly gamma-energy dependent in the 0.04 MeV to 1.25 MeV energy range. |
---|---|
ISSN: | 0021-1915 |