Instability of trochanteric hip fractures following internal fixation: A radiographic comparison of the Richards sliding screw-plate and the McLaughlin nail-plate

A comparison was made of the McLaughlin nail plate and the Richards sliding screw-plate techniques for fixation of trochanteric hip fractures. The series included 96 patients in each group. The fractures were followed radiographically for 3 months. Technical failures were encountered in 31 per cent...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta orthopaedica 1984-01, Vol.55 (5), p.517-520
Hauptverfasser: Moller, Bjarne Nue, Lucht, Ulf, Grymer, Frantz, Bartholdy, Niels Jacob
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A comparison was made of the McLaughlin nail plate and the Richards sliding screw-plate techniques for fixation of trochanteric hip fractures. The series included 96 patients in each group. The fractures were followed radiographically for 3 months. Technical failures were encountered in 31 per cent of the McLaughlin fractures and in 8 per cent of the Richards fractures; reoperation was performed in 9 per cent in McLaughlin vs none in the Richards fractures. The main failure was varus displacement in both groups, always combined with lateral cutting of the screw in the Richards fractures, and often combined with failure of the nail-plate junction in McLaughlin fractures. Our study has shown that the sliding screw-plate is superior to the nail plate in both stable and unstable fractures.
ISSN:1745-3674
0001-6470
1745-3682
DOI:10.3109/17453678408992950