Echocardiographic assessment of cardiac function in open chest dogs
Echocardiographic parameters of left ventricular function were compared with standard parameters in 5 open chest dogs. Cardiac output by echo compared with thermodilution showed a close correlation of r=0.952. Peak rate of decrease of left ventricular diameter (RDD) correlated with dp/dtmax r=0.826,...
Gespeichert in:
Veröffentlicht in: | Scandinavian cardiovascular journal : SCJ 1986, Vol.20 (1), p.39-46 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Echocardiographic parameters of left ventricular function were compared with standard parameters in 5 open chest dogs. Cardiac output by echo compared with thermodilution showed a close correlation of r=0.952. Peak rate of decrease of left ventricular diameter (RDD) correlated with dp/dtmax r=0.826, and 'normalized' RDD with dp/dtmax r=0.873. The peak rates of increase of LV diameter (RID) and 'normalized' RID correlated less with dp/dtmin, r=0.610 and r=0.642 respectively. Because of significant differences between the dogs, and because the results from all dogs induced into different hemodynamic states during the investigation were all pooled, the method proved reliable even under borderline conditions. We therefore think it may also be used in clinical situations. |
---|---|
ISSN: | 1401-7431 0036-5580 1651-2006 |
DOI: | 10.3109/14017438609105912 |