Analysis of Bone-Composite Interfacial Strengths

The strength characteristics of the interface between bone and a bone/porous metal composite were analyzed. The metal was 316L stainless steel. The average tensile strength of bone spicules ingrown to the porous metal was 46.5 MPa. This compares to a control bone sample strength of 89.7 MPa. The dif...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Artificial cells, blood substitutes, and immobilization biotechnology blood substitutes, and immobilization biotechnology, 1981, Vol.9 (1), p.47-55
Hauptverfasser: Davis, C. M., Shackelford, J. F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The strength characteristics of the interface between bone and a bone/porous metal composite were analyzed. The metal was 316L stainless steel. The average tensile strength of bone spicules ingrown to the porous metal was 46.5 MPa. This compares to a control bone sample strength of 89.7 MPa. The difference could be due to bone location and bone immaturity. The overall inter facial tensile strength (9.59 MPa) is necessarily lower since the spicules cover only a fraction of the inter facial cross-section. The overall interfacial strength had a wide range of scatter (s = ±4.11 MPa). This was probably due to inherent variations in bone strength with location. A population of samples using porous metal with average pore diameters under 100 μm exhibited measurably lower tensile strengths.