Voltage clamping circuit with ±100 mV precision in high-voltage OTA
It is shown that precise output voltage clamping levels can be achieved under any operating condition by clamping the input of operational transconductance amplifier to a process insensitive reference and multiplexing the levels based on comparator decision. This circuit was implemented in a 40 V bi...
Gespeichert in:
Veröffentlicht in: | Electronics letters 2016-05, Vol.52 (11), p.921-923 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | It is shown that precise output voltage clamping levels can be achieved under any operating condition by clamping the input of operational transconductance amplifier to a process insensitive reference and multiplexing the levels based on comparator decision. This circuit was implemented in a 40 V bipolar CMOS process. The fabricated circuit clamps the output voltage at 5.4 V with a precision of ±100 mV at 175°C on-chip junction temperature on the die. The input range for this circuit is between 100 mV and 25 V. |
---|---|
ISSN: | 0013-5194 1350-911X 1350-911X |
DOI: | 10.1049/el.2016.0571 |